Automatic Nucleic Acid Extractor YR01869-2

FabricanteKalstein

Description

The Automatic Nucleic Acid Extractor YR01869-2 is a cutting-edge instrument designed to streamline the nucleic acid extraction process. This advanced device features Rotary Mixing Technology (RMT), enabling simultaneous extraction of multiple samples without cross-interference. Its user-friendly interface, equipped with a 6.86-inch touchscreen and remote control via smartphones or tablets, contributed to winning the prestigious Red Dot Design Award 2021. Ideal for labs with varying assay requirements, its compact design is perfect for optimizing space and improving functionality across diverse laboratory environments.

Market Price

The market price of sophisticated devices like the Automatic Nucleic Acid Extractor YR01869-2 typically ranges between $8800 and $9680 USD. The price variance depends on the supplier and additional services included, such as technical support and warranty extensions. For laboratories looking to acquire this state-of-the-art equipment, it’s a valuable investment that promises high performance and durability. To get the best deal, consider generating an automatic quote through the Kalstein Plus platform, which offers personalized pricing and exclusive discounts.

Frequently Asked Questions

  • What samples can I process with the YR01869-2? The extractor is versatile and processes a wide array of samples, particularly those requiring high-precision nucleic acid extraction, including DNA and RNA.
  • Is it user-friendly? Absolutely, the YR01869-2 boasts a 6.86-inch multi-touchscreen and supports control via mobile devices, offering an intuitive operating experience.
  • How can I maintain the YR01869-2? Regular cleaning post-use and ensuring up-to-date software are key to maintaining optimal function.

Advantages and Disadvantages

Advantages:

  • High Flexibility: Execute multiple projects with 16 x n different outputs simultaneously.
  • Automated Workflow: Features like automatic reagent identification and over-the-air updates enhance efficiency by reducing manual input.
  • Advanced Safety Systems: UV lamps, internal negative pressure, and HEPA filtration minimize contamination risks.
  • Portability: Compact design allows easy relocation and setup in various lab settings.

Disadvantages:

  • Cost: The price may be prohibitive for smaller labs with limited financial resources.
  • Maintenance Requirements: Requires specialized knowledge for system maintenance and updates.

Product Use in the Field

The Automatic Nucleic Acid Extractor YR01869-2 finds extensive application in genetic research labs, clinical diagnostics, and biotechnology sectors. Its portability and ease of use make it a favorite in hospitals, forensic labs, and scientific research centers for nucleic acid extraction, sample analysis, and PCR projects. Its design supports mobile power sources, allowing for flexible and reliable performance even in demanding environments where speed and accuracy are critical.

Recommendations

To maximize the use of the Automatic Nucleic Acid Extractor YR01869-2, adhere to the manufacturer’s maintenance guidance, including regular device cleaning and protocol updates. The device’s capacity to run simultaneous tasks should be leveraged by conducting parallel assays, thus boosting lab productivity. Utilizing its UV disinfection system and HEPA filtration ensures high accuracy by preventing cross-contamination.

Features

  • Automatic reagent identification and control via mobile devices.
  • Innovative Rotary Mixing Technology for efficient sample processing.
  • User-friendly interface with a 6.86-inch touchscreen.
  • Compact and flexible design suitable for various lab settings.
  • Real-time monitoring and UV disinfection system.

Technical Specifications

Model YR01869-2
Throughput 16
Processing Volume 20-1700μL
Sample Processing Volume 200-500μL
Compatible Consumables Customized 96-deep-well plates, single 6-strip tubes
Inter-well Difference CV≤3%
Mixing Method Rotary mixing
Rotary Speed 100~3000rpm
Temperature Control Range Temperature control separately for lysis and elution.
Temperature range from 30°C to 120°C.
Temperature Control Accuracy Heating speed: 4.0±0.2°C/s.
Temperature accuracy: ±1.0°C.
Temperature uniformity:≤1.0°C.
Languages Chinese/English
Protocol Management Flexible to create, edit and delete protocols
Operation Mode Mode 1: Android systems in smartphones/tablets
Mode 2: 6.86 inch full-color LCD screen
Automatic Control Automatic opening and closing of the experiment cabin
Reagent Identification Automatic identification of reagent information and running the assays
Mixing Sleeve Monitoring Real-time monitoring of the mixing sleeves status in experiment
Magnetic Bead Residue ≤1%
Power Failure Protection Choose freely whether or not to continue the experiment when the power is on again after cutting off
Disinfection Ozone + UV disinfection
Auto Power-off Auto power-off after UV disinfection
Negative-Pressure Filtration Negative pressure HEPA filtration module
Connection Port Type USB port
Weight 7.4Kg (net)
Instrument Dimensions 210mm(L)*229mm(W)*242mm(H)
Power Supply AC220V, 50Hz

Additional information

Weight 11 kg
Dimensions 34 × 29 × 31 cm

Quote List

Quote List

No products in the list

Product categories

FAQ

Do you need help?

If you have any questions before processing the order, take a look at the most frequently asked questions

Do you want to know the cost of air shipping to your establishment?

Place your address in the payment area and you will automatically see the shipping to your door!

I am an institution; I need to know the price for several units; I would like to know the cost of the maritime freight