The YR05766 Orbital Shaker is a crucial tool for any laboratory setting, renowned for its reliable operation and precision in sample homogenization. Understanding how to interpret the results and readings from this equipment is essential for accurate data analysis and decision-making in various applications. This article delves deeply into this specific model, focusing on its features, functionalities, and best practices for accurate measurement interpretation.

Technical Data of the YR05766 Orbital Shaker

SpecificationDetails
ModelYR05766
Mode of AgitationOrbital/Convolution
ControlPID Microcomputer Control
MonitorDigital LED Display
AmplitudeØ30 mm
Frequency (rpm/min)15-240
Sensitivity (rpm)±2
Timer0-99 hours 59 minutes
Tray Size (mm)320×265
Number of Trays1
Total Size (mm)330x480x160
Power30W
Power SupplyAC 90-260V, 50-60HZ
Ambient Temperature-10 °C-65 °C

Principle of Operation of the YR05766

The YR05766 utilizes uniaxial transmission shaking technology which ensures smooth operation with minimal noise, making it suitable for sensitive laboratory environments. The design is optimized for a variety of applications where precise mixing is crucial. Understanding the mechanics behind its operation can aid users in maximizing its potential in experimental setups.

This specific model employs a brushless DC motor, which not only extends the lifespan of the shaker but also reduces maintenance requirements. In addition, the automatic overcurrent protection feature helps safeguard the equipment and other peripherals by automatically shutting off power during electrical surges.

Best Practices for Accurate Measurement Interpretation

To ensure accurate interpretation of measurements obtained from the YR05766, users should familiarize themselves with the display outputs. The digital LED display provides real-time data, including speed settings, time remaining on the timer, and any error messages. Understanding these indicators is vital for troubleshooting and ensuring that the shaker operates within its optimal parameters.

Moreover, it is important to regularly calibrate the device to maintain measurement accuracy. Calibration should be performed under controlled conditions and should adhere to any applicable protocols specific to the materials being mixed.

Common Misinterpretations and Their Solutions

Users may encounter certain common misinterpretations when reading results from the YR05766. For instance, a discrepancy in expected results may arise from incorrect speed settings or improper sample loading. It is critical to refer to the technical specifications and operational guides to rectify these issues.

In the event of unexpected readings, users should review the following:

  • Ensure the shaker is level and securely anchored.
  • Verify that the correct amplitude and frequency settings are in use based on the sample type.
  • Check for any visible wear or damage to the trays or components that may affect performance.

Environmental Requirements for Optimal Performance

The YR05766 operates effectively within a specified range of environmental conditions. It is essential to maintain the ambient temperature between -10 °C and 65 °C to avoid performance issues. Additionally, ensuring proper ventilation and stability in electrical supply contributes to the longevity and reliability of the device.

Users should consider preparing the site according to the following checklist:

RequirementDetails
Temperature-10 °C to 65 °C
Humidity20% to 80% RH (non-condensing)
Voltage/FrequencyAC 90-260V, 50-60HZ
ClearancesMinimum 15 cm around the unit

Frequently Asked Questions

How can I troubleshoot if the YR05766 does not power on?

If the YR05766 does not power on, check the power supply connection first. Ensure that the device is plugged into a functional outlet. If the indicator lights do not illuminate, there may be an internal fault or a blown fuse that requires professional attention.

What should I do if I receive an error code during operation?

Error codes on the YR05766 can indicate various issues. Refer to the user manual for specific error codes and their meanings. Most common solutions include resetting the machine or checking for correct settings based on the type of samples being processed.

What is the maximum capacity of the YR05766 for sample mixing?

The YR05766 is designed to handle a variety of sample sizes, but it is recommended to adhere to the tray size specifications, which is 320×265 mm. Overloading beyond the recommended weight can lead to inaccurate readings and potential damage.

How often should I perform maintenance on the YR05766?

Regular maintenance is crucial for the longevity of the YR05766. It is advisable to perform a thorough inspection and cleaning every month, along with periodic calibrations based on usage frequency and laboratory protocols.

Can the YR05766 be used for all types of samples?

While the YR05766 is versatile, the sample type will determine the appropriate settings for amplitude and frequency. Always refer to the guidelines for specific materials to ensure optimal mixing and prevent damage to both the equipment and samples.

How do I ensure consistent results using the YR05766?

For consistent results, always follow standardized protocols for mixing, including sample volumes and loading patterns. Regular calibration and adherence to the operational guidelines also play a vital role in achieving reproducibility in results.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Orbital Shaker YR05766 with all specifications, dimensions, accessories and quote options.
View product datasheet →