Description
The Electrolyte Analyzer is an advanced tool designed to provide accurate and rapid results in the analysis of serum, plasma, whole blood, and diluted urine. Equipped with automatic tracking and correction software for electrical potential, this device ensures stable performance. Additionally, its ability to detect and filter tiny bubbles prevents blockages, ensuring precise measurements. With real-time system status diagnostics and automatic residual liquid detection, accompanied by corresponding alarms, it significantly enhances operational safety.
This instrument offers automatic calibration and two-point correction, optimizing slope and intercept adjustments to ensure accuracy. Its wave and direct pipe washing methods minimize blockages and cross-contamination risks. The power failure protection allows storing up to 10,000 results, and its minimal consumption reduces consumable costs. The analyzer also includes an internal thermal printer and an RS232 interface, operating efficiently within a temperature range of 10-30°C and a relative humidity of 80%.
Market Price
The price of the Electrolyte Analyzer varies depending on the model and additional specifications. In the market, the price range for these devices is between $2,500 and $5,000. Factors such as storage capacity, the number of test parameters, and advanced features can influence the final cost. To get a specific and personalized quote, we invite you to use our Kalstein Plus platform, where you can generate an automatic quote quickly and easily.
Frequently Asked Questions
- What samples can the device analyze?
- The analyzer can work with serum, plasma, whole blood, and diluted urine.
- What is the measurement time?
- The measurement time is ≤30 seconds, ensuring rapid results.
- How many results can it store?
- It can store up to 10,000 test results, facilitating comprehensive tracking.
Advantages and Disadvantages
Advantages:
- Accuracy: Automatic calibration and two-point correction ensure precise results.
- Safety: Real-time diagnostics and automatic residual liquid detection enhance operational safety.
- Efficiency: Advanced washing methods reduce blockages and cross-contamination.
Disadvantages:
- Initial Cost: The initial investment can be high compared to other equipment.
- Maintenance: Requires regular maintenance to ensure optimal performance.
Field Use
The Electrolyte Analyzer is widely used in clinical laboratories, hospitals, and research centers. Its ability to provide rapid and precise results makes it ideal for emergency situations and routine tests. In the field, healthcare professionals rely on this device to monitor and evaluate patients’ electrolyte status, contributing to faster and more accurate diagnoses.
Recommendations
To maximize the use of the Electrolyte Analyzer, regular maintenance is crucial, including electrode cleaning and periodic calibration. Additionally, it is recommended to use specific cleaning solutions to avoid damage to internal components. It is essential that the staff is well-trained in handling the device to ensure accurate results and a long service life of the equipment.
Requesting a quote for this advanced Electrolyte Analyzer is easy and fast through our Kalstein Plus platform. Don’t miss the opportunity to improve your diagnostics and optimize your laboratory’s performance with this high-quality equipment. Generate your quote now and discover how this analyzer can transform your clinical practice!
Technical specifications
Model | YR06396 | YR06397 | YR06398 | YR06399 | YR06400 |
Sample | serum, plasma, whole blood and dilute urine | ||||
Analysis Method | ion selective electrode(ISE) | ||||
Measuring time | ≤30s | ||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | ||||
Storage | up to 10000 test results | ||||
Printer | Internal thermal printer | ||||
Interface | RS232 port | ||||
Temperature | 10-30°C | ||||
Relative Humidity | 80% | ||||
Atmospheric pressure | 86~106 kPa | ||||
Power supply | AC220V±22V, 50Hz±1Hz | ||||
Power | <120W | ||||
Test Parameters | K Na Cl | K Na CI TCO, AG | K Na Cl iCa nCa TCa pH | K Na Cl iCa nCa TCa pH TCO₂ AG | K Na Cl Li |
Model | YR064001 | YR06402 | YR06403 | YR06404 | YR06405 | YR06406 |
Sample | serum, plasma, whole blood and dilute urine | |||||
Analysis Method | ion selective electrode(ISE) | |||||
Measuring time | ≤30s | |||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | |||||
Storage | up to 10000 test results | |||||
Printer | Internal thermal printer | |||||
Interface | RS232 port | |||||
Temperature | 10-30°C | |||||
Relative Humidity | 80% | |||||
Atmospheric pressure | 86~106 kPa | |||||
Power supply | AC220V±22V, 50Hz±1Hz | |||||
Power | <120W | |||||
Test Parameters | K Na Cl iCa nCa TCa pH Li | K Na Cl iCa nCa TCa pH Li TCO₂ AG | K Na Cl iCa nCa TCa pH Mg | K Na Cl iCa nCa TCa pH Mg TCO₂ AG | K Na Cl iCa nCa TCa pH Mg Li TCO₂ AG |
K Na Cl iCa nCa TCa pH Mg Li
|
Accessories
Model | Description |
YRA264 | K Electrode |
YRA265 | K Electrode |
YRA266 | Cl Electrode |
YRA267 | Ca Electrode |
YRA268 | pH Electrode |
YRA269 | Li Electrode |
YRA270 | Mg Electrode |
YRA271 | Ref. Electrode |
YRA272 | Reagent Pack Calibration A 430ml; Calibration B 110ml; ( For Model H900 only) |
YRA273 | Reference Electrode Internal Solution – 10ml |
YRA274 | Electrode Internal
Solution – 3ml |
YRA275 | Activating Solution – 110ml |
YRA276 | QC Solution Level 2
(Water-based) – 110ml |
YRA277 | Cleaning Solution – 110ml |
YRA278 | Electrode Wash Solution (Protein Enzyme) -125mg (25mg/bottle x5) |
YRA278-1 | Electrode Wash Solution (Diluent) – 5ml ( 1 bottle) |