Description
4.3-inch color LCD screen, with backlight, suitable for working in various ambient light conditions. infusion monitoring system (optional), the status of each pump is displayed in real time at the central station via wireless transmission. Displays time, battery, infusion status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed number, I / V equipment, temperature of the medicine
- Large, backlit LCD display suitable for working in various ambient light conditions.
- Disposable IV set of any brand is suitable for this pump
- Three working modes: rate / volume / time mode
- Purge, KVO function
- The heating function is optional, suitable for infusing in winter or if there is a requirement for the temperature of the medicine.
- The central monitoring system is optional, the infusion status of each pump is displayed in real time at the central station via wireless transmission.
- Simple and convenient in operation, intuitive presence of working status.
- Audible and visible alarms
- Alarm: Infusion Full, Empty, Bad Signal, Malfunction, Occlusion, Door Open, Air Bubble, Low Battery, Setup Error, AC Power Off, Idle.
Technical description
Pump type | Drip Type Infusion Pump | ||
Pumping Form | peristaltic fingers | ||
Adjustable Fall Rate Range | 1 ~ 400 drops / min (step: 1 drop / min) | ||
Adjustable Volume Rate Range | 1 ~ 1200 ml / h (when 1 ~ 99.9 ml / h, step: 0.1 ml / h; greater than 99.9 ml / h, step: 1 ml / h) | ||
Flow Accuracy | Within 3% or so (using manufacturer’s designated IV kit or high quality calibrated IV kit) | ||
Mechanical precision | within 2% or so | ||
Purge Rate | 800ml / h | ||
KVO rate | 1 ml / hour (1 ~ 300 ml / hour) | ||
3 ml / h (more than 300 ml / h) | |||
Infusion Volume Range | 1 ml ~ 9999.9 ml (step: 0.1 ml) | ||
Maximum Accumulated Volume | 9999.9 ml (step: 0.1 ml) | ||
Time interval | 1 min ~ 9999 min (step: 1 min) | ||
Occlusion Alarm Threshold | Height: 800 mmHg + -200 mmHg (106.7 kPa + -26.7 kPa) | ||
Medium: 500 mmHg + -100 mmHg (66.7 kPa + -13.3 kPa) | |||
Low: 300 mmHg + -100 mmHg (40.7 kPa + -13.3 kPa) | |||
Alarm | Infusion Full, Empty, Bad Signal, Malfunction, Occlusion, Door Open, Air Bubble, Low Battery, Setup Error, AC Power Off, Idle. | ||
Air Bubble Detector Method | ultrasonic wave, sensitivity: greater than or equal | ||
25 l | |||
Fuse | F1AL / 250V (“F” indicates fast, “L” indicates low breaking power), 2 pieces (installed inside the pump). | ||
Power supply | AC 85 ~ 265V, 50 / 60Hz; | ||
Internal Battery | 11.1V rechargeable lithium-ion battery. Capacity: greater than or equal to 2000 mAh; | ||
The pump can run more than 4 hours at a flow rate of 25ml / h after charging for 8 hours (average flow rate specified by GB 9706.27-2005). | |||
Energy | less than or equal to 40VA | ||
Size | 188mm (length) x 198mm (width) x 228mm (height) | ||
Weight | 2.2 kg | ||
Environmental requirements | Transport | ||
Ambient temperature: -30 ° C ~ + 55 ° C | |||
Relative humidity: 20% ~ 95% (non-condensing) | |||
Atmospheric pressure: 70kPa ~ 106kPa | |||
Storage | |||
Ambient temperature: -30 ° C ~ + 55 ° C | |||
Relative humidity: 20% ~ 95% | |||
Atmospheric pressure: 70kPa ~ 106kPa | |||
Operation | |||
Ambient temperature: + 5 ~ + 40 ° C | |||
Relative humidity: 20% ~ 90% | |||
Atmospheric pressure: 86kPa ~ 106kPas | |||
Calibration function | disposable IV set of any brand is suitable for this pump | ||
Three Working Modes | Rate / volume / time mode | ||
Alarm | Infusion Full, Empty, Bad Signal, Malfunction, Occlusion, Door Open, Air Bubble, Low Battery, Setup Error, AC Power Off, Idle. |