Kalstein

Consumables, Spare Parts, and Compatible Accessories for the YR06104 Veterinary Anesthesia Ventilator

By Kalstein · Published on:

Category:articulos-de-productos

Consumables, Spare Parts, and Compatible Accessories for the YR06104 Veterinary Anesthesia Ventilator

Explore the essential consumables, spare parts, and accessories compatible with the YR06104 Veterinary Anesthesia Ventilator, ensuring optimal performance in va

3D available

Consumables, Spare Parts, and Compatible Accessories for the YR06104 Veterinary Anesthesia Ventilator

The YR06104 Veterinary Anesthesia Ventilator is specifically designed for diverse surgical scenarios involving animals. It is extensively employed in pet hospitals, animal clinics, scientific research institutions, and various educational settings. Understanding the consumables, spare parts, and compatible accessories for this model is crucial to maintaining its functionality and ensuring optimal patient care.

Understanding the YR06104 Veterinary Anesthesia Ventilator

The YR06104 features a turbo-driven design that does not require a high-pressure air source and operates solely with an oxygen concentrator. This characteristic allows for flexibility and adaptability in various clinical environments. With automated ventilation parameters based on the weight of the animal, the device is lightweight and portable, saving valuable space within medical facilities.

Technical Specifications of the YR06104

SpecificationDetails
ModelYR06104
Tidal Volume (TV)20-1500 ml
Breathing Rate (Freq)1-150 bpm
Spontaneous Breathing Rate (Freq_Spont)0-150 lpm
Inhalation/Exhalation Ratio (I:E)9.9:1 - 1:9 adjustable
Hold Time0-50%
Flow Trigger Sensitivity (F_Tring)0.5-20 L/min, OFF
Pressure Trigger Sensitivity (P_Tring)-1-20 cmH2O, OFF
End-Expiratory Pressure3-20 cmH2O, OFF
Inspiratory Time (T_Insp)0.1-12 s
Pressure Support (PS)0-60 cmH2O
Inspiratory Pressure (T_Insp)0-60 cmH2O
Minute Ventilation (MV)Display range: 0-99 L/min; Use range: 0-25 L/min
Inhaled Oxygen Concentration (FiO2)15-100%
Driving Gas Pressure (Press_Drive)0-900 kPa

Compatible Consumables for the YR06104

To maintain the performance of your YR06104 Veterinary Anesthesia Ventilator, it is essential to utilize appropriate consumables. Below is a list of the key consumables required for optimal operation:

  • Oxygen Concentrators: Ensure compatibility with the YR06104 for a reliable oxygen supply.
  • Ventilation Tubing: Use high-quality, flexible tubing to ensure effective gas exchange.
  • Filters: Replace filters regularly to maintain air quality and protect internal components.
  • Disposables: Employ disposable components like masks and breathing bags for sanitary practices.

Spare Parts for the YR06104

Regular maintenance and timely replacement of spare parts are crucial to preventing downtime and ensuring safety. The following spare parts are recommended:

  • Pressure Sensors: Monitor and control the pressure within the ventilator.
  • Flow Meters: Measure the flow rate of gases being delivered to the patient.
  • Control Circuit Boards: Essential for electronic functionality; ensure they are updated and functioning correctly.

Accessories for Enhanced Functionality

To enhance the functionality of the YR06104, consider the following accessories:

  • Extended Battery Packs: For increased portability and operation during emergencies.
  • Mobile Stands: Facilitate easy maneuverability in clinical settings.
  • Calibration Kits: Ensure accuracy and reliability in measurements.

Frequently Asked Questions

What are the main consumables required for the YR06104 Veterinary Anesthesia Ventilator?

The primary consumables include oxygen concentrators, ventilation tubing, filters, and disposables such as masks and breathing bags. These elements are essential for ensuring the ventilator operates effectively and safely.

How often should I replace the filters in the YR06104?

Filters should be inspected regularly and replaced as needed, typically every few weeks depending on usage and environmental conditions. Regular replacement is crucial to maintain air quality and protect the ventilator's internal components.

What spare parts are essential for the YR06104 to prevent downtime?

Key spare parts include pressure sensors, flow meters, and control circuit boards. Keeping these components in stock can help minimize downtime due to repairs.

Can I use third-party accessories with the YR06104?

While third-party accessories may be compatible, it is recommended to use manufacturer-approved accessories to ensure optimal performance and maintain warranty coverage.

Where can I find replacement parts and consumables for the YR06104?

Replacement parts and consumables can typically be sourced from authorized suppliers or directly from the manufacturer to guarantee compatibility and quality.

Is the YR06104 suitable for all animal types?

The YR06104 is designed for versatility and can be used in various surgical scenarios across different animal types, making it suitable for clinical, educational, and research purposes.

What is the expected lifespan of the YR06104 and its components?

The expected lifespan of the YR06104 is generally around 5-10 years with proper maintenance, while specific components may have shorter lifespans based on usage and care.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Turbo-driven Veterinary Anesthesia Ventilator YR06104 with all specifications, dimensions, accessories and quote options.
View product datasheet →